摘要:

目的 分析基质辅助激光解吸电离飞行时间质谱(MALDI⁃TOF MS)检测支气管肺泡灌洗液(BALF)对涂阴或无痰肺结核(PTB)的诊断价值。方法 以 2020 年 1 月至 2021 年 12 月安徽省胸科医院收治的 87 例疑似涂阴或无痰 PTB 患者为研究对象,对其 BALF 进行 MALDI⁃TOF MS、SAT⁃TB、Gene⁃Xpert 及BD960 法检测,并对其诊断价值进行比较。结果 MALDI⁃TOF MS 诊断涂阴或无痰 PTB 敏感性为 68.5%(37/54),优于SAT⁃TB 13.0%(7/54)、Gene⁃Xpert 40.7%(22/54)、BD960法27.8%(15/54)(均P < 0.01)。MALDI⁃TOF MS 法 AUC 值为 0.827,优于 SAT⁃TB 0.550、Gene⁃Xpert 0.704、BD960 法 0.639(均 P < 0.01)。MALDI⁃TOF MS 分别联合上述 3 种方法的 AUC 并不优于其单独检测。 结论 MALDI⁃TOF MS 是较准确的辅助诊断涂阴或无痰PTB 的新方法,有较好的应用前景。

关键词: 基质辅助激光解吸电离飞行时间质谱, 结核, 支气管肺泡灌洗液, 诊断

Abstract:

Objective To investigate the efficacy of matrix assisted laser desorption/Ionization ⁃ time of flight mass spectrometry(MALDI⁃TOF MS)for the diagnosis of smear⁃negative or sputum⁃scarce pulmonary tuber⁃ culosis(PTB)by testing bronchoalveolar lavage fluid(BALF). Methods BALF of 87 patients with suspected smear⁃negative or sputum⁃scarce tuberculosis were tested by MALDI⁃TOF MS,SAT⁃TB,Gene⁃Xpert and BD960 from January 2020 to December 2021 in Anhui Chest Hospital. The results from those methods were compared. Results The sensitivity of MALDI⁃TOF MS for diagnosing smear⁃negative or sputum⁃scarce PTB was 68.5%(37/ 54),which was better than that of SAT⁃TB 13.0%(7/54),or Gene⁃Xpert 40.7%(22/54),or BD960 27.8%(15/54 all P < 0.01). The AUC value of MALDI⁃TOF MS was 0.827,which was better than that of SAT⁃TB 0.550,or Gene ⁃Xpert 0.704,or BD960 0.639(all P < 0.01). Combining MALDI ⁃TOF MS with any one of the other three methods did not produce a better AUC value than using it alone. Conclusion MALDI⁃TOF MS appears to be a more accurate method in assisting the diagnosis of smear⁃negative or sputum⁃scarce PTB.

Key words: matrix assisted laser desorption/ionization ?time of flight mass spectrometry,  , tuberculosis,  , bronchoalveolar lavage fluid,  , diagnosis