实用医学杂志 ›› 2021, Vol. 37 ›› Issue (16): 2093-2097.doi: 10.3969/j.issn.1006⁃5725.2021.16.012

• 临床研究 • 上一篇    下一篇

基于4D⁃CTA技术测量头颈血管循环时间的可行性

张小勇1,2,3 胡容2,3 曾宪春2,3 王荣品2,3 李文航2,3 伍瑶斌2,3 余晖1,4   

  1. 1 贵州医科大学医学影像学院(贵阳 550002);2 贵州省人民医院放射科(贵阳 550002);3 贵州省智能医学 影像分析与精准诊断重点实验室(贵阳 550002);4 贵州医科大学附属医院影像科(贵阳 550002)

  • 出版日期:2021-08-25 发布日期:2021-08-25
  • 通讯作者: 余晖 E⁃mail:331693861@qq.com
  • 基金资助:
    贵州省科技计划项目(编号:黔科合平台人才[2019]5803 号)

Measurement of circulation time of head and neck vessels with 4D⁃CTA technology

ZHANG Xiaoyong*,HU Rong,ZENG Xianchun,WANG Rongpin,LI Wenhang,WU Yaobin,YU Hui.
  

  1. School of Medical Imaging,Guizhou Medical University,Guiyang 550002,China;*Department of Radiology,Guizhou People′ s Hospital,Guiyang 550002,China;*Key Laboratory of Smart Medical Imaging Analysis and Precise Diagnosis,Guiyang 550002,China 

  • Online:2021-08-25 Published:2021-08-25
  • Contact: YU Hui E⁃mail:331693861@qq.com

摘要:

目的 探讨基于头颈范围 4D⁃CTA 数据测量颈脑动、静脉血管循环时间的可行性,为指导头颈范围 CT 血管成像时机的选择提供参考。方法 回顾性收集 2018 1 月至 2021 3 月行头颈范围 4D⁃ CTA 成像的患者 298 例,测量头颈范围动脉(主动脉弓、颈总动脉、椎动脉、大脑中动脉 M1、基底动脉中段) 和静脉(颈内静脉、乙状窦、上矢状窦)的 CT 值和峰值时间,计算主动脉弓至颅内动脉、主动脉弓至上矢状 窦、上矢状窦至颈内静脉之间的循环时间、动脉系统和静脉系统平均峰值时间及两者之差;对比不同性 别、BMI(< 18.5 kg/m2、18.5 ~ 23.9 kg/m2、> 23.9 kg/m2 )、体质量(< 60 kg、60 ~ 80 kg、> 80 kg)患者之间峰值时 间的差异。结果 本组研究中主动脉弓至颅内动脉、主动脉弓至上矢状窦、上矢状窦至颈内静脉之间的循 环时间分别为(1.91 ± 0.78)、(6.61 ± 1.40)、(1.52 ± 1.43)s;动脉系统峰值时间为(21.77 ± 3.09)s,静脉系统 峰值时间为(28.76 ± 3.68)s,动静脉峰值时间差为(6.99 ± 1.01)s;按患者性别分组比较,男性主动脉弓峰 值时间、动脉系统峰值时间、静脉系统峰值时间、动静脉峰值时间差分别为(20.65 ± 3.61)、(22.55 ± 2.83)、 29.90 ± 3.13)、(7.36 ± 0.90)s,女性分别为(19.00 ± 3.05)、(20.56 ± 3.15)、(26.99 ± 3.83)、(6.44 ± 0.92)s 差异均有统计学意义(P < 0.05);按患者 BMI 和体质量分组比较,各组动静脉峰值时间差相近,动静脉峰 值时间随体质量增加逐渐延长,但组间差异均无统计学意义(P > 0.05)。结论 除女性峰值时间更早,动静脉循环时间更短外,不同体质量、不同 BMI 之间峰值时间和循环时间无显著差异,基于 4D⁃CTA 技术测 量头颈血管循环时间的临床应用切实可行,最佳动脉期与最佳静脉期间隔时间为6.99 s。

关键词:

颈脑血管循环时间,  , 4D?CTA,  , 头颈血管CT , 成像,  , 计算机断层扫描

Abstract:

Objective To explore the feasibility of measuring of arterial and venous circulation time of jugular brain based with 4D⁃CTA data of head and neck range,and to provide reference for CT angiography of head and neck range. Method A retrospective analysis of 298 patients who underwent 4D ⁃CTA imaging of head and neck range from January 2018 to March 2021 was conducted. The CT value and peak time of the arteries(aortic arch,common carotid artery,vertebral artery,middle cerebral artery M1,middle section of basilar artery)and veins(internal jugular vein,sigmoid sinus,superior sagittal sinus)in the head and neck area were measured. The circulation time from aortic arch to intracranial artery,from aortic arch to superior sagittal sinus,from superior sag⁃ ittal sinus to internal jugular vein,the average peak time of arterial system and venous system and the difference between them were calculated. The differences of peak time among patients with different genders,BMI(< 18.5 18.5 ~ 23.9,23.9 kg/m2)and body weight(< 60 kg,60 ~ 80 kg,> 80 kg)were compared. Result In this study the circulation time from aortic arch to intracranial artery ,from aortic arch to superior sagittal sinus and from superior sagittal sinus to internal jugular vein was(1.91 ± 0.78)s,(6.61 ± 1.40)s and(1.52 ± 1.43)s,respectively. The peak time of arterial system and venous system was(21.77 ± 3.09)s and(28.76 ± 3.68)s respectively,and the difference between the peak time of arteriovenous system was(6.99 ± 1.01s). The peak time of aortic arch arterial system,venous system and arteriovenous peak time in male and female patients were(20.65 ± 3.61)s 22.55 ± 2.83)s,(29.90 ± 3.13)s,and(7.36 ± 0.90)s and(19.00 ± 3.05)s,(20.56 ± 3.15)s,(26.99 ± 3.83)s,and(6.44 ± 0.92)s,respectively. The difference was statistically significant(P < 0.05). According to the BMI and body weight,the peak time difference of arteriovenous injection was similar,and the peak time of arteriovenous injection gradually prolonged with the increase of body weight,but no between ⁃group statistical significance was found(P > 0.05). Conclusion Except the earlier peak time and shorter arteriovenous circulation time in women there is no significant difference in peak time and circulation time between patients with different body weights and different BMI. The clinical application of 4D ⁃CTA technology to measure the circulation time of head and neck vessels was feasible,and the interval between the optimal arterial period and the optimal venous period was 6.99 s.

Key words:

cervico ?cerebral vascular circulation time, 4D CTA, CT imaging of head and neck vessels, computed tomography