The Journal of Practical Medicine >
Application of SonoVCADheart for assessing fetal coronary artery morphology
Received date: 2026-03-18
Online published: 2026-07-14
Objective To evaluate the diagnostic accuracy and clinical utility of SonoVCADheart, a volume ultrasound-based computer-aided diagnosis system for the fetal heart, in assessing fetal coronary artery morphology compared with conventional fetal echocardiography. Methods A total of 322 high-risk pregnant women in the second and third trimesters were prospectively enrolled between July 2024 and September 2025. All participants underwent both conventional fetal echocardiography and SonoVCADheart imaging. Postnatal echocardiography served as the reference standard. Diagnostic performance for coronary artery origin, course, and luminal diameter was compared between the two modalities. Twenty-two cases were excluded due to inadequate image quality (four-chamber view score ≤ 2), leaving 300 for final analysis. Results Among the 300 analyzed fetuses, postnatal follow-up confirmed normal coronary anatomy in 278 and abnormalities in 22 (7.33%), comprising 2 anomalous origins and 20 diffuse dilations (all associated with fetal growth restriction). SonoVCADheart demonstrated significantly higher overall diagnostic accuracy than conventional echocardiography (P 0.05). Specifically, SonoVCADheart identified 20 true positives, 2 false positives, 276 true negatives, and 2 false negatives (sensitivity 90.9%, specificity 99.3%), whereas conventional echocardiography detected 16 true positives, 7 false positives, 271 true negatives, and 6 false negatives (sensitivity 72.7%, specificity 97.5%). Although sensitivity, specificity, positive predictive value, and negative predictive value were numerically higher for SonoVCADheart, these differences did not reach statistical significance (all P 0.05). For coronary artery diameter measurements, Pearson correlation coefficients between the two methods were 0.865 for the left main and 0.859 for the right coronary artery (both P 0.05). Intraclass correlation coefficients (ICCs) were 0.848 and 0.853, respectively, indicating strong inter-method agreement. Conclusions SonoVCADheart provides superior diagnostic accuracy and more reliable quantitative measurements of fetal coronary artery morphology compared with conventional echocardiography. It effectively reduces missed diagnoses and misclassifications, particularly for coronary origin anomalies and secondary dilations, offering valuable support for precise prenatal detection, classification, and clinical management.
Qunxiang XIE , Xiaoling JIANG , Fang PAN . Application of SonoVCADheart for assessing fetal coronary artery morphology[J]. The Journal of Practical Medicine, 2026 , 42(13) : 2300 -2308 . DOI: 10.3969/j.issn.1006-5725.2026.13.005
| [1] | GóMEZ-ARRIAGA P I, ESCRIBANO D, GóMEZ-MONTES E, et al. Prenatal diagnosis of isolated coronary artery fistula: Systematic review, analysis of perinatal prognostic factors and case report[J]. J Matern Fetal Neonatal Med, 2023, 36(1): 2206938. doi:10.1080/14767058.2023.2206938 . |
| [2] | PISESKY A, NIELD L E, ROSENTHAL J, et al. Comparison of pre- and postnatally diagnosed coronary artery fistulae: Echocardiographic features and clinical outcomes[J]. J Am Soc Echocardiogr, 2022, 35(12): 1322-1335. doi:10.1016/j.echo.2022. 07.015 . |
| [3] | 邹鹏, 孙善权, 刘琴, 等. 超声心动图对室间隔完整型肺动脉瓣闭锁和极重度肺动脉瓣狭窄胎儿的分型、评估及其出生后随访[J]. 中国循证儿科杂志, 2021, 16(3): 192-196. doi:10.3969/j.issn.1673-5501.2021.03.004 . |
| [4] | KANAGALA S G, GUPTA V, DUNN G V, et al. Narrative review of anomalous origin of coronary arteries: Pathophysiology, management, and treatment[J]. Curr Cardiol Rev, 2023, 19(6): e300523217447. doi:10.2174/1573403x19666230530095341 . |
| [5] | 谷孝艳, 王静怡, 范佳祺, 等. 胎儿超声心动图指征在先天性心脏病产前诊断中的应用价值[J]. 中国实用妇科与产科杂志, 2022, 38(10): 993-995.doi:10.19538/j.fk2022100109 . |
| [6] | 沈珍珍, 沈双双, 汪晓敏, 等. 胎儿超声心动图联合母体血清标志物对胎儿先天性心脏病的诊断价值[J]. 中国妇幼保健, 2024, 39(1): 165-168.doi:10.19829/j.zgfybj.issn.1001-4411. 2024.01.043 . |
| [7] | 励娜, 赵博文, 陈志鑫, 等. 超声心动图定量正常中晚孕期胎儿动脉导管Z-评分的研究[J]. 现代实用医学, 2023, 35(7): 906-908, 封3. doi:10.3969/j.issn.1671-0800.2023.07.020 . |
| [8] | HU W Y, YU Y C, DAI L Y, et al. Reliability of sonography-based volume computer aided diagnosis in the normal fetal heart[J]. J Ultrasound Med, 2021, 40(5): 953-962. doi:10.1002/jum.15469 . |
| [9] | UITTENBOGAARD L B, HAAK M C, VAN VUGT J M G. Feasibility of automated 3-dimensional fetal cardiac screening in routine ultrasound practice[J]. J Ultrasound Med, 2009, 28(7): 881-888. doi:10.7863/jum.2009.28.7.881 . |
| [10] | ZENG Q H, CHEN S X, TIAN J. Application of fetal left and right ventricular outflow tract sections obtained by SonoVCADheart technology in the diagnosis of fetal cardiac malformations at 11-17 weeks of gestation [J]. Chin J Birth Health Hered,2023,31 (1):153-158. doi:10.13404/j.cnki.cjbhh.2023.01.028 . |
| [11] | 戴丽雅, 赵博文, 余燕成, 等. 基于容积超声的胎儿心脏计算机辅助诊断技术在定量评估主动脉和肺动脉内径中的价值[J]. 中华超声影像学杂志, 2020, 29(1): 31-36. doi:10.3760/cma.j.issn.1004-4477.2020.01.006 . |
| [12] | WANG Y, WANG L, ZANG H, et al. Comparison of different ultrasonic screening methods and analysis of high risk factors for fetal cardiac malformation in second trimester of pregnancy[J]. Pediatr Cardiol, 2025, 46(4): 769-777. doi:10.1007/s00246-024-03525-6 . |
| [13] | MOON-GRADY A J, DONOFRIO M T, GELEHRTER S, et al. Guidelines and recommendations for performance of the fetal echocardiogram: An update from the American society of echocardiography[J]. J Am Soc Echocardiogr, 2023, 36(7): 679-723. doi:10.1016/j.echo.2023.04.014 . |
| [14] | WANG A, DOAN T T, REDDY C, et al. Artificial intelligence in fetal and pediatric echocardiography[J]. Children, 2025, 12(1): 14. doi:10.3390/children12010014 . |
| [15] | GEMBICKI M, SCHARF J L, DRACOPOULOS C, et al. Maximal reduction of STIC acquisition time for volumetric assessment of the fetal heart-benefits and limitations of semiautomatic fetal intelligent navigation echocardiography (FINE) static mode[J]. J Clin Med, 2022, 11(14): 4062. doi:10.3390/jcm11144062 . |
| [16] | ZHAO L, WU Y, CHEN S, et al. Feasibility study on prenatal cardiac screening using four-dimensional ultrasound with spatiotemporal image correlation: A multicenter study[J]. PLoS One, 2016, 11(6): e0157477. doi:10.1371/journal.pone.0157477 . |
| [17] | 郭又问. 时空关联成像技术在胎儿心脏检查中的应用研究[D]. 长沙: 中南大学, 2010. .doi:10.7666/d.y1719460 . |
| [18] | 陈晔, 唐颖, 朱善良, 等. 超声心动图诊断儿童冠状动脉异常起源于肺动脉[J]. 中国医学影像学杂志, 2023, 31(11): 1140-1144. doi:10.3969/j.issn.1005-5185.2023.11.003 . |
| [19] | GARCIA-CANADILLA P, DE VRIES T, GONZALEZ-TENDE-RO A, et al. Structural coronary artery remodelling in the rabbit fetus as a result of intrauterine growth restriction[J]. PLoS One, 2019, 14(6): e0218192. doi:10.1371/journal.pone.0218192 . |
| [20] | NIU K X, LI T G, YE J J, et al. Detection of fetal right coronary artery–right ventricle fistula with pulmonary valve atresia using HDlive Flow with spatiotemporal image correlation[J]. Quant Imaging Med Surg, 2025, 15(8): 7690-7696. doi:10.21037/qims-24-2214 . |
| [21] | D′ALBERTI E, MAPPA I, RIZZO G. Accuracy of 3D ultrasound in the prenatal diagnosis of congenital heart diseases[M]//3D Ultrasound of Fetal Heart. Cham: Springer Nature Switzerland, 2025: 35-48. doi:10.1007/978-3-031-87175-7_3 . |
| [22] | HU X, SHEN J, HE C, et al. A retrospective analysis: CCTA vs. TTE in diagnosing coronary artery fistula[J]. Curr Med Imaging, 2025, 21: e15734056333289. doi:10.2174/0115734056333289 250311184106 . |
| [23] | GON?ALVES L F. Four-dimensional ultrasound examination of the fetal heart using spatiotemporal image correlation (STIC)[M]//Fetal Cardiology. Boca Raton: CRC Press,2018:192-212. doi:10.1201/9781315117769-14 . |
| [24] | CALVES L, LEE W, ESPINOZA J, et al. Examination of the fetal heart by four-dimensional (4D) ultrasound with spatio-temporal image correlation (STIC)[J]. Ultrasound Obstet Gynecol,2006,27 (3):336-348. doi:10.1002/uog.2707 . |
| [25] | GINDES L, HEGESH J, WEISZ B, et al. Three and four dimensional ultrasound: a novel method for evaluating fetal cardiac anomalies [J]. Prenat Diagn,2009,29(7):645-653. doi:10.1002/pd.2279 . |
/
| 〈 |
|
〉 |