The Journal of Practical Medicine >
Radiotherapy treatment comparison of liver SBRT between 4D⁃CT and deep inspiration breath hold troughmagnetic resonance imaging
Received date: 2024-12-20
Online published: 2025-04-23
Objective To compare the radiotherapy treatment accuracy between 4D-CT and DIBH following liver SBRT, and to illustrate the relevant factors. Methods A retrospective analysis was conducted on the clinical data of 28 liver cancer patients who underwent SBRT from November 2020 to July 2024, all of whom exhibited and localizedmorphological changes on magnetic resonance imaging (MRI). Among them, 8 patients used DIBH, and 17 patients used 4D- CT. The areas of localized MRI-morphologic alterations (MMA) were delineated on post-therapeutic MRI. Different isodose structures were generated on the planning CT, and after performing deformation registration based on the liver's region of interest (ROI), the most suitable isodose structure and MMA contours were compared to obtain quantitative accuracy indices. Correlations between factors such as GTV, PTV, liver volume, and volume changes, and the accuracy indices were analyzed. Results The DSC accuracy for the DIBH group was (0.66 ± 0.17), range 0.32 ~ 0.90, while the DSC accuracy for the 4D CT group was (0.69 ± 0.10), range 0.49 ~ 0.80. T-test analysis showed no significant statistical differences in accuracy indices between the DIBH and 4D CT groups (P < 0.05). Correlation analysis revealed that, in both groups, distance-based indices (HD, MDA, 3D-CoMD) were more strongly correlated with accuracy indices than conformality indices (DSC, CIMI). Conclusion There was no significant difference in treatment accuracy between the DIBH and 4D-CT groups, although the maximum accuracy in the DIBH group was higher than that in the 4D-CT group. This method can serve as an bench-markingtool for evaluating the accuracy of liver SBRT.It is recommended to prioritize the use of conformality indices, DSC and CIMI, when assessing the treatment accuracy of liver cancer SBRT using this approach.
Huiling YE , Zhengchaoyi CHEN , Yihan HUANG , Yingjie ZHANG , Xiangbin ZHANG , Yuehu PU , Renming ZHONG . Radiotherapy treatment comparison of liver SBRT between 4D⁃CT and deep inspiration breath hold troughmagnetic resonance imaging[J]. The Journal of Practical Medicine, 2025 , 41(7) : 1044 -1049 . DOI: 10.3969/j.issn.1006-5725.2025.07.017
| 1 | CHOI S H, LEE B M, KIM J, et al. Efficacy of stereotactic ablative radiotherapy in patients with oligometastatic hepatocellular carcinoma: a phase ii study[J]. J Hepatol, 2024, 81(1): 84-92. doi:10.1016/j.jhep.2024.03.003 |
| 2 | BAE S H, CHUN S J, CHUNG J H, et al. Stereotactic body radiation therapy for hepatocellular carcinoma: meta-analysis and international stereotactic radiosurgery society practice guidelines[J]. Int J Radiat Oncol Biol Phys, 2024, 118(2): 337-351. doi:10.1016/j.ijrobp.2023.08.015 |
| 3 | OHRI N, TOMé W A, MéNDEZ ROMERO A, et al. Local control after stereotactic body radiation therapy for liver tumors[J]. Int J Radiat Oncol Biol Phys, 2021, 110(1): 188-195. doi:10.1016/j.ijrobp.2017.12.288 |
| 4 | SENGUPTA C, NGUYEN D T, MOODIE T, et al. The first clinical implementation of real-time 6 degree-of-freedom image-guided radiotherapy for liver sabr patients[J]. Radiother Oncol, 2024, 190: 110031. doi:10.1016/j.radonc.2023.110031 |
| 5 | WEBSTER A, MUNDORA Y, CLARK C H, et al. A systematic review of the impact of abdominal compression and breath-hold techniques on motion, inter-fraction set-up errors, and intra-fraction errors in patients with hepatobiliary and pancreatic malignancies[J]. Radiother Oncol, 2024, 201: 110581. doi:10.1016/j.radonc.2024.110581 |
| 6 | 钱涵, 汪红艳, 王凡. 呼吸触发前瞻门控在早期非小细胞肺癌立体定向放射治疗中剂量学优势[J]. 实用医学杂志, 2023, 39(1): 86-91. |
| 7 | SIMPSON D R, LAWSON J D, NATH S K, et al. Utilization of advanced imaging technologies for target delineation in radiation oncology[J]. J Am Coll Radiol, 2009, 6(12): 876-883. doi:10.1016/j.jacr.2009.08.006 |
| 8 | GABRY? D, KULIK R, TRELA K, et al. Dosimetric comparison of liver tumour radiotherapy in all respiratory phases and in one phase using 4dct[J]. Radiother Oncol, 2011, 100(3): 360-364. doi:10.1016/j.radonc.2011.09.006 |
| 9 | PERSSON G F, SCHERMAN RYDH?G J, JOSIPOVIC M, et al. Deep inspiration breath-hold volumetric modulated arc radiotherapy decreases dose to mediastinal structures in locally advanced lung cancer[J]. Acta Oncol, 2016, 55(8): 1053-1056. doi:10.3109/0284186x.2016.1142115 |
| 10 | KLEIN T J, GILL S, EBERT M A, et al. CyberKnife xsight versus fiducial-based target-tracking: a novel 3d dosimetric comparison in a dynamic phantom[J]. Radiat Oncol, 2022, 17(1): 154. doi:10.1186/s13014-022-02123-1 |
| 11 | BODA-HEGGEMANN J, JAHNKE A, CHAN M K H, et al. In-vivo treatment accuracy analysis of active motion-compensated liver sbrt through registration of plan dose to post-therapeutic mri-morphologic alterations[J]. Radiother Oncol, 2019, 134: 158-165. doi:10.1016/j.radonc.2019.01.023 |
| 12 | ZHONG R, WANG J, JIANG X, et al. Hypofraction radiotherapy of liver tumor using cone beam computed tomography guidance combined with active breath control by long breath-holding[J]. Radiother Oncol, 2012, 104(3): 379-385. doi:10.1016/j.radonc.2011.11.007 |
| 13 | BROCK K K, MUTIC S, MCNUTT T R, et al. Use of image registration and fusion algorithms and techniques in radiotherapy: report of the aapm radiation therapy committee task group no. 132[J]. Med Phys, 2017, 44(7): e43-e76. doi:10.1002/mp.12256 |
| 14 | MUNKRES J R. Topology[M]. 2nd ed. Upper Saddle River NJ: Prentice Hall Inc, 2000: xvi, 537. |
| 15 | CHALANA V, KIM Y M. A methodology for evaluation of boundary detection algorithms on medical images[J]. IEEE Trans Med Imaging, 1997, 16(5): 642-652. doi:10.1109/42.640755 |
| 16 | PADDICK I, LIPPITZ B. A simple dose gradient measurement tool to complement the conformity index[J]. J Neurosurg, 2006, 105 Suppl: 194-201. doi:10.3171/sup.2006.105.7.194 |
| 17 | GRéGOIRE V, MACKIE T R. State of the art on dose prescription, reporting and recording in intensity-modulated radiation therapy (icru report no. 83)[J]. Cancer Radiother, 2011, 15(6): 555-559. doi:10.1016/j.canrad.2011.04.003 |
| 18 | JUNG J, KIM H, YOON S M, et al. Targeting accuracy of image-guided stereotactic body radiation therapy for hepatocellular carcinoma in real-life clinical practice: in vivo assessment using hepatic parenchymal changes on gd-eob-dtpa-enhanced magnetic resonance images[J]. Int J Radiat Oncol Biol Phys, 2018, 102(4): 867-874. doi:10.1016/j.ijrobp.2018.05.018 |
| 19 | BODA-HEGGEMANN J, JAHNKE A, CHAN M K H, et al. Direct dose correlation of mri morphologic alterations of healthy liver tissue after robotic liver sbrt[J]. Strahlenther Onkol, 2018, 194(5): 414-424. doi:10.1007/s00066-018-1271-9 |
| 20 | DREHER C, SARRIA G R R, MIEBACH G, et al. Long-term characterization of mri-morphologic alterations after active motion-compensated liver sbrt: a multi-institutional pooled analysis[J]. Acta Oncol, 2023, 62(3): 281-289. doi:10.1080/0284186x.2023.2187707 |
| 21 | SHARMA M, NANO T F, AKKATI M, et al. A systematic review and meta-analysis of liver tumor position variability during sbrt using various motion management and igrt strategies[J]. Radiother Oncol, 2022, 166: 195-202. doi:10.1016/j.radonc.2021.11.022 |
| 22 | VAN HERK M. Errors and margins in radiotherapy[J]. Semin Radiat Oncol, 2004, 14(1): 52-64. doi:10.1053/j.semradonc.2003.10.003 |
| 23 | FARRUGIA B, KNIGHT K, WRIGHT C, et al. A prospective trial demonstrating the benefit of personalized selection of breath-hold technique for upper-abdominal radiation therapy using the active breathing coordinator[J]. Int J Radiat Oncol Biol Phys, 2021, 111(5): 1289-1297. doi:10.1016/j.ijrobp.2021.08.001 |
| 24 | GUO B, STEPHANS K, WOODY N, et al. Online verification of breath‐hold reproducibility using kv‐triggered imaging for liver stereotactic body radiation therapy[J]. J Appl Clin Med Phys, 2023, 24(9): e14045. doi:10.1002/acm2.14045 |
| 25 | 叶惠玲, 钟仁明. 磁共振影像学改变评估肝癌立体定向放疗精度的研究进展[J]. 实用医学杂志, 2024, 40(22): 3119-3123. |
| 26 | BOTTICELLA A, LEVY A, AUZAC G, et al. Tumour motion management in lung cancer: a narrative review[J]. Transl Lung Cancer Res, 2021, 10(4): 2011-2017. doi:10.21037/tlcr-20-856 |
| 27 | ZENG L, WANG X, ZHOU J, et al. Analysis of the amplitude changes and baseline shifts of respiratory motion using intra-fractional cbct in liver stereotactic body radiation therapy[J]. Phys Med, 2022, 93: 52-58. doi:10.1016/j.ejmp.2021.12.007 |
/
| 〈 |
|
〉 |