实用医学杂志 ›› 2024, Vol. 40 ›› Issue (21): 3095-3100.doi: 10.3969/j.issn.1006-5725.2024.21.021
收稿日期:
2024-03-28
出版日期:
2024-11-10
发布日期:
2024-11-19
通讯作者:
华宝桐
E-mail:kyfyyhbt@126.com
基金资助:
Yimei HUANG,Lulu ZHAO,Baotong. HUA()
Received:
2024-03-28
Online:
2024-11-10
Published:
2024-11-19
Contact:
Baotong. HUA
E-mail:kyfyyhbt@126.com
摘要:
心房颤动(房颤)是一种以心房激活不协调和心房收缩无效为特征的室上性心律失常,发病率高,常并发卒中、心力衰竭和心动过速致心功能降低诱发心肌病等不良事件,给患者及家庭造成巨大负担。综合管理房颤至关重要,可有效降低房颤病死率、致残率及改善预后。但传统心电图监测大概率漏诊了无症状及阵发性房颤。植入式心电事件监测仪(insertable cardiac monitor,ICM)作为新一代监测工具,可弥补传统心律监测工具缺点,提供实时心律监测心电图并为使用者提供警报。ICM已广泛应用于医学各领域,临床主要应用于不明原因晕厥患者,近年其适应证研究逐渐扩展到房颤监测,但在临床实践中仍未受到重视。结合相关文献,该文就ICM在房颤中的应用及最新研究进展进行综述,结合优缺点进行评估,让医师在临床实践中重视其应用,以期为管理房颤提供帮助。
中图分类号:
黄义梅,赵璐露,华宝桐. 植入式心电事件监测仪在房颤中的应用及进展[J]. 实用医学杂志, 2024, 40(21): 3095-3100.
Yimei HUANG,Lulu ZHAO,Baotong. HUA. Application effect of insertable cardiac monitorin atrial fibrillation monitoring[J]. The Journal of Practical Medicine, 2024, 40(21): 3095-3100.
1 |
SHI S, TANG Y, ZHAO Q, et al. Prevalence and risk of atrial fibrillation in China: A national cross-sectional epidemiological study[J]. Lancet Reg Health West Pac, 2022, 23:100439. doi:10.1016/j.lanwpc.2022.100439
doi: 10.1016/j.lanwpc.2022.100439 |
2 |
YUAN K, ZHAO P, WANG L. Molecular mechanism of atrial remodeling in patients with aging atrial fibrillation under the expression of microRNA-1 and microRNA-21[J]. Bioengineered, 2021, 12(2):12905-12916. doi:10.1080/21655979.2021.2008668
doi: 10.1080/21655979.2021.2008668 |
3 |
JANUARY C T, WANN L S, CALKINS H, et al. 2019 AHA/ACC/HRS Focused Update of the 2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society in Collaboration With the Society of Thoracic Surgeons[J]. Circulation, 2019, 140(2):e125-e151. doi:10.1161/cir.0000000000000719
doi: 10.1161/cir.0000000000000719 |
4 |
AGGARWAL G, AGGARWAL S, ALLA V, et al. Subcutaneouscardiac Rhythm Monitors A Comprehensive Review[J]. JAFIB, 2021, 13(5):2387. doi:10.4022/jafib.2387
doi: 10.4022/jafib.2387 |
5 |
ASSAF A, THEUNS D A, MICHELS M, et al. Usefulness of insertable cardiac monitors for risk stratification: current indications and clinical evidence[J]. Expert Rev Med Devices, 2023, 20(2):85-97. doi:10.1080/17434440.2023.2171862
doi: 10.1080/17434440.2023.2171862 |
6 |
UNGAR A, PESCINI F, RAFANELLI M, et al. Detection of subclinical atrial fibrillation after cryptogenic stroke using implantable cardiac monitors[J]. Eur J Intern Med, 2021, 92:86-93. doi:10.1016/j.ejim.2021.06.022
doi: 10.1016/j.ejim.2021.06.022 |
7 |
SCHNABEL R B, HAEUSLER K G, HEALEY J S, et al. Searching for Atrial Fibrillation Poststroke: A White Paper of the AF-SCREEN International Collaboration[J]. Circulation, 2019, 140(22):1834-1850. doi:10.1161/circulationaha.119.040267
doi: 10.1161/circulationaha.119.040267 |
8 |
HINDRICKS G, POTPARA T, DAGRES N, et al. 2020 ESC Guidelines for the diagnosis and management of atrial fibrillation developed in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS): The Task Force for the diagnosis and management of atrial fibrillation of the European Society of Cardiology (ESC) Developed with the special contribution of the European Heart Rhythm Association (EHRA) of the ESC[J]. Eur Heart J, 2020, 42(5):373-498. doi:10.1093/eurheartj/ehaa612
doi: 10.1093/eurheartj/ehaa612 |
9 |
LU Y, DIAO S S, HUANG S J, et al. Insertable cardiac monitors for detection of atrial fibrillation after cryptogenic stroke: a meta-analysis[J]. Neurol Sci, 2021, 42(10):4139-4148. doi:10.1007/s10072-021-05104-6
doi: 10.1007/s10072-021-05104-6 |
10 |
NOUBIAP J J, AGBAEDENG T A, KAMTCHUM-TATUENE J, et al. Rhythm monitoring strategies for atrial fibrillation detection in patients with cryptogenic stroke: A systematic review and meta-analysis[J]. Int J Cardiol Heart Vasc, 2021, 34:100780. doi:10.1016/j.ijcha.2021.100780
doi: 10.1016/j.ijcha.2021.100780 |
11 |
NOUBIAP J J, THOMAS G, MIDDELDORP M E, et al. Atrial fibrillation detection using insertable cardiac monitor after stroke: A real-world cohort study[J]. J Cardiovasc Electrophysiol, 2023, 34(1):142-146. doi:10.1111/jce.15744
doi: 10.1111/jce.15744 |
12 |
RATAJCZAK-TRETEL B, LAMBERT A T, AL-ANI R, et al. Underlying causes of cryptogenic stroke and TIA in the nordic atrial fibrillation and stroke (NOR-FIB) study - the importance of comprehensive clinical evaluation[J]. BMC Neurol, 2023, 23(1):115. doi:10.1186/s12883-023-03155-0
doi: 10.1186/s12883-023-03155-0 |
13 |
ILIODROMITIS K, LENARCZYK R, SCHERR D, et al. Patient selection, peri-procedural management, and ablation techniques for catheter ablation of atrial fibrillation: an EHRA survey[J]. Europace, 2023, 25(2):667-675. doi:10.1093/europace/euac236
doi: 10.1093/europace/euac236 |
14 |
FALASCONI G, PENELA D, SOTO-IGLESIAS D, et al. Personalized pulmonary vein antrum isolation guided by left atrial wall thickness for persistent atrial fibrillation[J]. Europace, 2023, 25(5): euad118. doi:10.1093/europace/euad118
doi: 10.1093/europace/euad118 |
15 |
YAMAGUCHI Y, SOHARA H, TAKEDA H, et al. Long-Term Results of Radiofrequency Hot Balloon Ablation in Patients With Paroxysmal Atrial Fibrillation: Safety and Rhythm Outcomes[J]. J Cardiovasc Electrophysiol, 2015, 26(12):1298-1306. doi:10.1111/jce.12820
doi: 10.1111/jce.12820 |
16 |
MASUDA M, ASAI M, IIDA O, et al. Additional low‐voltage‐area ablation in patients with paroxysmal atrial fibrillation: results of the randomized controlled VOLCANO trial[J]. J Am Heart Assoc, 2020, 9(13):e015927. doi:10.1161/JAHA.120.015927
doi: 10.1161/JAHA.120.015927 |
17 |
SCHIAVONE M, GASPERETTI A, MONTEMERLO E, et al. Long-term comparisons of atrial fibrillation ablation outcomes with a cryoballoon or laser-balloon: A propensity-matched analysis based on continuous rhythm monitoring[J]. Hellenic J Cardiol, 2022, 65:1-7. doi:10.1016/j.hjc.2022.03.006
doi: 10.1016/j.hjc.2022.03.006 |
18 |
LEE S H, KIM T H, OH Y S, et al. Usefulness of an Implantable Loop Recorder in Diagnosing Unexplained Syncope and Predictors for Pacemaker Implantation[J]. J Korean Med Sci, 2020, 35(2):e11. doi:10.3346/JKMS.2020.35.E11
doi: 10.3346/JKMS.2020.35.E11 |
19 |
SULKE N, SUGIHARA C, HONG P, et al. The benefit of a remotely monitored implantable loop recorder as a first line investigation in unexplained syncope: the EaSyAS Ⅱ trial[J]. Europace, 2016, 18(6):912-918. doi:10.1093/europace/euv228
doi: 10.1093/europace/euv228 |
20 | 熊雁, 刘明江, 陶剑虹, 等. 不明原因晕厥患者基于长程心电数据的病因分析[J].中华心律失常杂志, 2023, 27(1): 66-70. |
21 |
LETSAS KP, SAPLAOURAS A, MILILIS P, et al. Diagnostic yield of implantable loop recorders: Results from the Hellenic registry[J]. Hellenic J Cardiol, 2024, S1109-9666(24)00108-8. doi:10.1016/j.hjc.2024.05.004
doi: 10.1016/j.hjc.2024.05.004 |
22 |
GIADA F, GULIZIA M, FRANCESE M, et al. Recurrent unexplained palpitations (RUP) study comparison of implantable loop recorder versus conventional diagnostic strategy[J]. J Am Coll Cardiol, 2007, 49(19):1951-1956. doi:10.1016/j.jacc.2007.02.036
doi: 10.1016/j.jacc.2007.02.036 |
23 |
中华医学会心电生理和起搏分会, 中国医师协会心律学专业委员会, 中国房颤中心联盟心房颤动防治专家工作委员会. 心房颤动:目前的认识和治疗建议(2021)[J]. 中华心律失常学杂志, 2022, 26(1):74. doi:10.3760/cma.j.cn113859-20211224-00264
doi: 10.3760/cma.j.cn113859-20211224-00264 |
24 |
POTPARA T S, LIP G Y H, BLOMSTROM-LUNDQVIST C, et al. The 4S-AF Scheme (Stroke Risk; Symptoms; Severity of Burden; Substrate): A Novel Approach to In-Depth Characterization (Rather than Classification) of Atrial Fibrillation[J]. Thromb Haemost, 2021, 121(3):270-278. doi:10.1055/S-0040-1716408
doi: 10.1055/S-0040-1716408 |
25 |
BRIOSA E GALA A, POPE M, LEO M, et al. Accuracy of AF burden detection with the new Confirm Rx with Sharp-sense technology[J]. EP Europace, 2022. DOI:10.1093/europace/euac053.173 .
doi: 10.1093/europace/euac053.173 |
26 |
ASSAF A, THEUNS D, SAKHI R, et al. Accuracy of atrial fibrillation detection by an insertable cardiac monitor in patients undergoing catheter ablation: Results of the BioVAD study[J]. Ann Noninvasive Electrocardiol, 2022, 27(3):e12960. doi:10.1111/anec.12960
doi: 10.1111/anec.12960 |
27 |
DE WITH R R, ERKüNER Ö, RIENSTRA M, et al. Temporal patterns and short-term progression of paroxysmal atrial fibrillation: data from RACE V[J]. Europace, 2020, 22(8):1162-1172. doi:10.1093/europace/euaa123
doi: 10.1093/europace/euaa123 |
28 |
KAPLAN R M, KOEHLER J, ZIEGLER P D, et al. Stroke Risk as a Function of Atrial Fibrillation Duration and CHA(2)DS(2)-VASc Score[J]. Circulation, 2019, 140(20):1639-1646. doi:10.1161/circulationaha.119.041303
doi: 10.1161/circulationaha.119.041303 |
29 |
王斌,胡丹,王芳芳. 血清尿酸及脑钠肽水平与射血分数保留心衰房颤患者房颤结构重构关系[J]. 实用医学杂志, 2023, 39(20):2633-2637. doi:10.3969/j.issn.1006-5725.2023.20.014
doi: 10.3969/j.issn.1006-5725.2023.20.014 |
30 |
HINDRICKS G, POTPARA T, DAGRES N, et al. 2020 ESC Guidelines for the diagnosis and management of atrial fibrillation developed in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS): The Task Force for the diagnosis and management of atrial fibrillation of the European Society of Cardiology (ESC) Developed with the special contribution of the European Heart Rhythm Association (EHRA) of the ESC[J]. Eur Heart J, 2021, 42(5):373-498. doi:10.1093/eurheartj/ehaa945
doi: 10.1093/eurheartj/ehaa945 |
31 | 张鹏祥,杜王,张郝,等. 抗凝治疗与房颤患者血浆神经源性外泌体中T⁃tau 蛋白和Aβ1⁃42含量变化的关系[J]. 实用医学杂志, 2022, 38(4):459-463. |
32 |
QURASHI A A AL, RASHEED F, SIDDIQI A R, et al. Insertable cardiac monitoring devices versus external cardiac monitoring for detecting atrial fibrillation and preventing the recurrence of stroke: A systematic review and meta-analysis[J]. J Electrocardiol, 2023, 77:29-36. doi:10.1016/j.jelectrocard.2022.11.007
doi: 10.1016/j.jelectrocard.2022.11.007 |
33 | 梁士楚, 王翠, 宋晨宇,等. 心房颤动射频消融术后长期抗凝可行性及安全性的Meta分析和试验序贯分析[J]. 中国循环杂志, 2020, 35(11):1121-1128. |
34 |
FRIBERG L, TABRIZI F, ENGLUND A. Catheter ablation for atrial fibrillation is associated with lower incidence of stroke and death: data from Swedish health registries[J]. Eur Heart J, 2016, 37(31):2478-2487. doi:10.1093/eurheartj/ehw087
doi: 10.1093/eurheartj/ehw087 |
35 |
ARAI M, OKUMURA Y, NAGASHIMA K, et al. Adverse Clinical Events during Long-Term Follow-Up After Catheter Ablation of Atrial Fibrillation[J]. Int Heart J, 2019, 60(4):812-821. doi:10.1536/ihj.18-517
doi: 10.1536/ihj.18-517 |
36 |
POTHINENI N V K, AMANKWAH N, SANTANGELI P, et al. Continuous rhythm monitoring-guided anticoagulation after atrial fibrillation ablation[J]. J Cardiovasc Electrophysiol, 2021, 32(2):345-353. doi:10.1111/jce.14864
doi: 10.1111/jce.14864 |
37 |
WILLEMS S, BOROF K, BRANDES A, et al. Systematic, early rhythm control strategy for atrial fibrillation in patients with or without symptoms: the EAST-AFNET 4 trial[J]. Eur Heart J, 2022, 43(12):1219-1230. doi:10.1093/eurheartj/ehab593
doi: 10.1093/eurheartj/ehab593 |
38 |
KUNISS M, PAVLOVIC N, VELAGIC V, et al. Cryoballoon ablation vs. antiarrhythmic drugs: first-line therapy for patients with paroxysmal atrial fibrillation[J]. Europace, 2021, 23(7):1033-1041. doi:10.1093/europace/euab029
doi: 10.1093/europace/euab029 |
39 |
BERLIN S, GOETTE A, SUMMO L, et al. Assessment of OMT-28, a synthetic analog of omega-3 epoxyeicosanoids, in patients with persistent atrial fibrillation: Rationale and design of the PROMISE-AF phase Ⅱ study[J]. Int J Cardiol Heart Vasc, 2020, 29:100573. doi:10.1016/j.ijcha.2020.100573
doi: 10.1016/j.ijcha.2020.100573 |
40 |
CHU A F, RAJAGOPAL G, SARKAR S. The missing link: Unlocking the power of cardiac rhythm monitoring device based QT interval detection[J]. Pacing Clin Electrophysiol, 2022, 45(3):401-409. doi:10.1111/pace.14431
doi: 10.1111/pace.14431 |
41 |
STOLEN C, ROSMAN J, MANYAM H, et al. Preliminary results from the LUX-Dx insertable cardiac monitor remote programming and performance (LUX-Dx PERFORM) study[J]. Clin Cardiol, 2023, 46(1):100-107. doi:10.1002/clc.23930
doi: 10.1002/clc.23930 |
42 |
IBRAHIM O A, DREW D, HAYES C J, et al. Implantable loop recorders in the real world: a study of two Canadian centers[J]. J Interv Card Electrophysiol, 2017, 50(2):179-185. doi:10.1007/s10840-017-0294-y
doi: 10.1007/s10840-017-0294-y |
43 |
AFZAL M R, MEASE J, KOPPERT T, et al. Incidence of false-positive transmissions during remote rhythm monitoring with implantable loop recorders[J]. Heart Rhythm, 2020, 17(1):75-80. doi:10.1016/j.hrthm.2019.07.015
doi: 10.1016/j.hrthm.2019.07.015 |
44 |
DE COSTER M, DEMOLDER A, DE MEYER V, et al. Diagnostic accuracy of R-wave detection by insertable cardiac monitors[J]. Pacing Clin Electrophysiol, 2020, 43(5):511-517. doi:10.1111/pace.13912
doi: 10.1111/pace.13912 |
45 |
CHENG Y-J, OUSDIGIAN KT, SARKAR S, et al. B-Po04-036 innovative artificial intelligence application reduces false pause alerts while maintaining perfect true pause alert sensitivity for insertable cardiac monitors[J]. Heart Rhythm, 2021, 18(8):S293-S294. doi:10.1016/j.hrthm.2021.06.732
doi: 10.1016/j.hrthm.2021.06.732 |
46 |
TANKUT S S, HUANG D T, ZAREBA W, et al. Insertable cardiac monitor-guided early intervention to reduce atrial fibrillation burden following catheter ablation: Study design and clinical protocol (ICM-REDUCE-AF trial)[J]. Ann Noninvasive Electrocardiol, 2023, 28(2):e13043. doi:10.1111/anec.13043
doi: 10.1111/anec.13043 |
47 |
QUARTIERI F, HARISH M, CALÒ L, et al. New insertable cardiac monitors show high diagnostic yield and good safety profile in real-world clinical practice: results from the international prospective observational SMART Registry[J]. Europace, 2023, 25(5): euad068. doi:10.1093/europace/euad068
doi: 10.1093/europace/euad068 |
[1] | 袁宸,赵霞,吴嘉宝,严花. S1P在哮喘中的研究现状及应用前景[J]. 实用医学杂志, 2024, 40(7): 936-940. |
[2] | 宁燕虹,徐苑珊,李晓华,李仕华,杨桢华,廖蕴华,潘玲. 沙库巴曲缬沙坦治疗慢性肾脏病5期难治性高血压患者的临床观察[J]. 实用医学杂志, 2024, 40(4): 543-548. |
[3] | 王璇璐,胡颖,彭年春,许婧,何娟,肖帮惠,王睿,徐毅,张淼. 甲泼尼龙联合吗替麦考酚酯治疗中重度活动性Graves眼病[J]. 实用医学杂志, 2024, 40(21): 3067-3075. |
[4] | 吴君,顾晓峰. 乌灵胶囊联合胞磷胆碱钠胶囊治疗老年突发性耳聋[J]. 实用医学杂志, 2024, 40(21): 3090-3094. |
[5] | 文贤,曾显峰,苏蕊雅. 伊伐布雷定片联合左西孟旦在急性心肌梗死合并心力衰竭患者中的应用[J]. 实用医学杂志, 2024, 40(2): 242-247. |
[6] | 张永旭,王岳松,杨达,董学滨,曹明勇,汪韶君,涂克祥. 左束支区域起搏对房室传导阻滞患者术后新发房性心律失常的影响[J]. 实用医学杂志, 2024, 40(13): 1846-1850. |
[7] | 念思琦,赵璐露,华宝桐. 心房颤动导管消融术后房性心律失常复发的研究进展[J]. 实用医学杂志, 2024, 40(10): 1338-1343. |
[8] | 罗乾友, 谢玲 曾安宁, 王章兰 杨钦宇 潘竟 刘军 刘淑英 . 左心耳封堵术后封堵器周围残余漏的临床研究进展 [J]. 实用医学杂志, 2023, 39(6): 778-782. |
[9] | 武阳 陆翰杰 水会锋 . 既往免疫经治的晚期非小细胞肺癌患者接受安罗替尼联合PD⁃1单抗的疗效及安全性 [J]. 实用医学杂志, 2023, 39(5): 572-578. |
[10] | 唐海涛,王娴,晁廷霞,王凤梅,贾文玲,梁春辉,张文华. 富马酸丙酚替诺福韦治疗失代偿期乙型肝炎肝硬化患者疗效和安全性[J]. 实用医学杂志, 2023, 39(24): 3249-3254. |
[11] | 罗城,郭胜杰,张志凌,周芳坚. 国产单孔手术机器人辅助腹腔镜下肾部分切除术的可行性及安全性分析[J]. 实用医学杂志, 2023, 39(24): 3275-3280. |
[12] | 陈贤达, 马楠, 郭胜杰, 刘振华, 尧凯. 安罗替尼单药及联合方案治疗晚期嗜铬细胞瘤/副神经节瘤的疗效与安全性研究[J]. 实用医学杂志, 2023, 39(23): 3106-3110. |
[13] | 聂时淮,郭丽旭,刘咏,陈荣新. DR⁃泪道造影术在泪道阻塞性疾病中的临床运用价值[J]. 实用医学杂志, 2023, 39(22): 2969-2973. |
[14] | 王斌,胡丹,王芳芳. 血清尿酸及脑钠肽水平与射血分数保留心衰房颤患者房颤结构重构关系[J]. 实用医学杂志, 2023, 39(20): 2633-2637. |
[15] | 肖鹏 李伟娟 梅家转 白桦 栗敏 刘桂举 李瑞君. 阿帕替尼联合PD⁃1单抗后线治疗晚期结直肠癌患者的疗效和安全性[J]. 实用医学杂志, 2023, 39(2): 255-261. |
阅读次数 | ||||||
全文 |
|
|||||
摘要 |
|
|||||